A 1401 m2 Balcke-Durr falling film plate evaporator was installed at Bundaberg Sugar’s Tableland factory for the 2001 season. Testing of this evaporator was carried out during the 2001 and 2002 seasons. Initially the scaling rate was rapid and heat transfer performance was disappointing. However, following modifications to the juice distributor the heat transfer performance was improved and the scaling rate was reduced. With the new juice distributor heat transfer coefficients typically ranged from 5 000 W.m-2.K-1 immediately after a clean to about 2 600 W.m-2.K-1 after 14 days of operation. The paper describes experiences with operation of the evaporator and the heat transfer performance.

File Type: pdf
File Size: 182 KB
Categories: Public
Tags: ASSCT
Author: KG Dunn, Nj Sichter, R Broadfoot, RB Tyson, RL Lee
Publication Year: